Item No.
U460
Adjusting the conveying sensor
Description
Compensates the threshold value of the side multi tray's multi feed sensor.
Purpose
If more than one sheet is fed at a time, modify the threshold depending on the environment.
Method
1. Press the OK key.
2. Select [SMT].
SMT
Method
1. Select the item.
Conveying Sensor
On/Off Config
Setting: [Conveying Sensor]
1. Select the item.
Threshold(S)
Threshold(M)
Sensor(Non-P)
Sensor
Execute
Setting: [Threshold(S)/(M)]
1. Select the item.
2. Change the setting value using the numeric keys.
Threshold(S)
Threshold(M)
3. Press the OK key. The value is set.
Method: [Execute]
1. Select [Execute].
2. Press the OK key. Calibration is executed.
Display
Settings of multiple feed sensor on the side multi tray
Display
Multi feed sensor settings/Calibration
Multi feed sensor On/Off settings
Display
Paper feeding threshold settings
Multi feed threshold settings
Empty paper sensor display
Displaying sensor value when paper is present
Executing the calibration
Display
Paper feeding threshold settings
Multi feed threshold settings
Description
Description
Description
Description
Description
1-3-116
2MN/2N1-1
Setting
Initial
range
setting
0 to 254
0
0 to 254
0