1-5-3 Optical section

(1) Detaching and refitting the LSU

Procedure
1. Remove the paper conveying unit (see
page 1-5-32).
2. Remove the left upper cover (see page
1-5-44).
3. Remove the toner filter.
4. Remove the left filter cover and the left
filter.
5. Remove two transfer belt filters.
6. Remove the left cover lid.
7. Open the front cover and remove screw
A.
8. Remove
four
screws B and then
remove the left cover.
Toner filter
Left cover
Left filter
1-5-17
Transfer belt filters
Screw B
Left cover lid
Left filter cover
Figure 1-5-26
2MN/2N1-1
Screw A
Screws