Connector
Pin
YC1
1
GND
Connected to
2
FEED_MOT_REM
engine PWB
3
FEED_MOT_CLK
4
FEED_MOT_RDY
5
FEED_MOT_DIR
6
FEED_CL1_REM
7
FEED_CL2_REM
8
ASIST_CL2
9
LIFT_MOT2_REM
10
GND
11
LIFT_MOT1_REM
1
12
CAS2_WID
13
CAS2_LNG3
14
CAS2_LNG2
15
CAS2_LNG1
16
CAS1_WID
17
CAS1_LNG3
18
CAS1_LNG2
19
CAS1_LNG1
20
GND
21
CAS2_QUANT2
22
CAS2_QUANT1
23
CAS1_QUANT2
24
CAS1_QUANT1
25
LIFT_MOT1_LOC
K
26
LIFT_MOT2_LOC
K
27
CURRENT_SIG
28
V-FEED_CL
29
COVER_OPEN
30
FEED2_SENS
31
CAS1_P0
32
CAS1_LIFT_UP
33
GND
34
CAS1_EMPTY
Signal
I/O
-
-
I
0/3.3 V DC
I
0/3.3 V DC (pulse) PFM clock signal
O
0/3.3 V DC
I
0/3.3 V DC
I
0/24 V DC
I
0/24 V DC
I
0/24 V DC
I
0/24 V DC
-
-
I
0/24 V DC
O
0/3.3 V DC
O
0/3.3 V DC
O
0/3.3 V DC
O
0/3.3 V DC
O
0/3.3 V DC
O
0/3.3 V DC
O
0/3.3 V DC
O
0/3.3 V DC
-
-
O
0/3.3 V DC
O
0/3.3 V DC
O
0/3.3 V DC
O
0/3.3 V DC
O
0/3.3 V DC
O
0/3.3 V DC
O
0/3.3 V DC
I
0/24 V DC
O
0/3.3 V DC
O
0/3.3 V DC
O
0/3.3 V DC
O
0/3.3 V DC
-
-
O
0/3.3 V DC
Voltage
Ground
PFM: On/Off
PFM ready signal
PFM drive switch signal
PFCL1: On/Off
PFCL2: On/Off
ASCL2: On/Off
LM2: On/Off
Ground
LM1: On/Off
PWSW2: On/Off
PLSW2: On/Off
PLSW2: On/Off
PLSW2: On/Off
PWSW1: On/Off
PLSW1: On/Off
PLSW1: On/Off
PLSW1: On/Off
Ground
PGS2(L): On/Off
PGS2(U): On/Off
PGS1(L): On/Off
PGS1(U): On/Off
LM1 lock signal
LM2 lock signal
Current signal
PCCL: On/Off
PCCSW: On/Off
PFPCS1: On/Off
FS1: On/Off
LS1: On/Off
Ground
PS1: On/Off
2-3-57