Setting The Fuser Motor Control - Kyocera FS-C8600DN Service Manual

Hide thumbs Also See for FS-C8600DN:
Table of Contents

Advertisement

Item No.
U052

Setting the fuser motor control

Description
Enters the sensor data values described on the supplied sheet provided when the loop sensor is
replaced and performs correction processing for the fuser motor.
Purpose
To perform when replacing the loop sensor or paper conveying unit.
Method
1. Press the OK key.
2. Select the item.
Set Loop S
Adj Loop S
Loop S Control
Set Loop S Valid
Chk Loop S
Method: [Set Loop Sensor]
1. Select [Scanning Board1].
2. Enter the sensor data value of supplied sheet DATA1 using
the numeric keys.
3. Select [Scanning Board2].
4. Enter the sensor data value of supplied sheet DATA2 using
the numeric keys.
5. Press the OK key. The value is set.
Setting: [Loop Sensor Control]
1. Select the item.
2. Change the setting value using the numeric keys.
ScanBoard1
ScanBoard2
3. Press the OK key. The setting is set.
Display
Enter the data value for loop sensor
Perform the adjustment of the loop sensor sensitivity
Set the loop sensor detection control
Sets the presence or absence of the loop sensor
Display the data value for loop sensor
Display
Scanning Board1 adjustment
Scanning Board2 adjustment
Description
Description
Description
1-3-39
How to read the sensor data value
(e.g.)
1
2
3
4
5
6
7
8
9
0
3 6 4
2MN/2N1