Short-Circuited Developer Thermistor C; Short-Circuited Developer Thermistor M; Short-Circuited Developer Thermistor Y Wire; Developer Unit K/C Type Mismatch Error - Kyocera FS-C8600DN Service Manual

Hide thumbs Also See for FS-C8600DN:
Table of Contents

Advertisement

Code
Contents
7252
Short-circuited developer
thermistor C
The sensor input sampling is
less than 69.
7253
Short-circuited developer
thermistor M
The sensor input sampling is
less than 69.
7254
Short-circuited developer
thermistor Y wire
The sensor input sampling is
less than 69.
7401
Developer unit K type mis-
match error
Absence of the developer unit
K is detected.
7402
Developer unit C type mis-
match error
Absence of the developer unit
C is detected.
Causes
Defective connec-
Reinsert the connector. Also check for conti-
tor cable or poor
nuity within the connector cable. If none,
contact in the con-
replace the cable.
nector.
Developer unit C and front PWB (YC13)
Front PWB (YC2) and engine PWB (YC10)
Defective devel-
Replace developer unit C (see page 1-5-29).
oper thermistor C.
Defective engine
Replace the engine PWB and check for cor-
PWB.
rect operation (see page 1-5-49).
Defective connec-
Reinsert the connector. Also check for conti-
tor cable or poor
nuity within the connector cable. If none,
contact in the con-
replace the cable.
nector.
Developer unit M and front PWB (YC11)
Front PWB (YC2) and engine PWB (YC10)
Defective devel-
Replace developer unit M (see page 1-5-
oper thermistor M.
29).
Defective engine
Replace the engine PWB and check for cor-
PWB.
rect operation (see page 1-5-49).
Defective connec-
Reinsert the connector. Also check for conti-
tor cable or poor
nuity within the connector cable. If none,
contact in the con-
replace the cable.
nector.
Developer unit Y and front PWB (YC15)
Front PWB (YC2) and engine PWB (YC10)
Defective devel-
Replace developer unit Y (see page 1-5-29).
oper thermistor Y.
Defective engine
Replace the engine PWB and check for cor-
PWB.
rect operation (see page 1-5-49).
Defective connec-
Reinsert the connector. Also check for conti-
tor cable or poor
nuity within the connector cable. If none,
contact in the con-
replace the cable.
nector.
Developer unit K and front PWB (YC9)
Front PWB (YC2) and engine PWB (YC10)
Different type of
Install the correct developer unit.
the developer unit
is installed.
Defective connec-
Reinsert the connector. Also check for conti-
tor cable or poor
nuity within the connector cable. If none,
contact in the con-
replace the cable.
nector.
Developer unit C and front PWB (YC13)
Front PWB (YC2) and engine PWB (YC10)
Different type of
Install the correct developer unit.
the developer unit
is installed.
1-4-65
Check procedures/
corrective measures
2MN/2N1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fs-c8650dnEcosys fs-c8600dnEcosys fs-c8650dn

Table of Contents