Connector
Pin
YC6
17
FSR_CL_REM
Connected to
18
FSR_MOT_REM
feed PWB 1
19
FSR_MOT_CLK
20
FSR_MOT_RDY
21
FSR_MOT_DIR
22
FSR_MOT_BRK
23
GND
24
MPF_TABLE
25
MPF_WID1
26
MPF_WID2
27
MPF_WID3
28
MPF_LNG
29
GND
30
MPF_PPR
31
MPF_UP
32
MPF_DOWN
33
MPF_JAM
34
MPF_CL
35
MPF_LIF2
36
MPF_LIFT1
37
GND
38
TC_MOT_LOCK
39
TC_TONER_LED
40
TONER_FULL
41
TC_TONER_VCO
NT
42
INTER_LOCK
43
DU2_MOT_PD
44
DU2_MOT_CLK
45
DU2_MOT_REM
46
GND
47
DU_OPEN
48
DU_FAN
49
PRESS_MOT_RE
M1
50
PRESS_MOT_RE
M2
51
PRESS_RLS_SE
NS
Signal
I/O
-
-
O
0/3.3 V DC
0/3.3 V DC (pulse) FUM clock signal
O
0/3.3 V DC
O
0/3.3 V DC
O
0/3.3 V DC
-
-
I
0/3.3 V DC
I
0/3.3 V DC
I
0/3.3 V DC
I
0/3.3 V DC
I
0/3.3 V DC
-
-
I
0/3.3 V DC
I
0/3.3 V DC
I
0/3.3 V DC
I
0/3.3 V DC
O
0/24 V DC
O
0/24 V DC
O
0/24 V DC
-
-
-
-
-
-
-
-
-
-
-
-
O
0/3.3 V DC
O
0/3.3 V DC (pulse) DUM2 clock signal
O
0/3.3 V DC
-
-
I
0/3.3 V DC
-
-
O
0/24 V DC
O
0/24 V DC
I
0/3.3 V DC
Voltage
Not used
FUM: On/Off
FUM ready signal
FUM drive switch signal
FUM break signal
Ground
MPTSW: On/Off
MPPWSW: On/Off
MPPWSW: On/Off
MPPWSW: On/Off
MPPLSW: On/Off
Ground
MPPS: On/Off
MPLS1: On/Off
MPLS2: On/Off
MPFS: On/Off
MPPFCL: On/Off
MPLM: On/Off
MPLM: On/Off
Ground
Not used
Not used
Not used
Not used
Not used
DUM2 control signal
DUM2/DUCL2: On/Off
Ground
DUCSW: On/Off
Not used
TRRM: On/Off
TRRM: On/Off
TRRS: On/Off
2-3-14