Code
Contents
8140
DF tray motor error 1
When the main tray has
started ascending, DF tray
sensor 1 or DF tray upper sur-
face sensor does not turn on
within 20 s.
8150
DF tray motor error 2
When the main tray has
descended, DF tray sensor 1
or DF tray upper surface sen-
sor does not turn off within
5 s.
Causes
Defective connec-
Reinsert the connector. Also check for conti-
tor cable or poor
nuity within the connector cable. If none,
contact in the con-
replace the cable.
nector (4000-sheet
DF tray motor and DF main PWB (YC16)
finisher).
DF tray sensor 1 and DF main PWB (YC22)
DF tray upper surface sensor and DF main
PWB (YC21, YC13)
Defective connec-
Reinsert the connector. Also check for conti-
tor cable or poor
nuity within the connector cable. If none,
contact in the con-
replace the cable.
nector (1000-sheet
DF tray motor and DF main PWB (YC14)
finisher).
DF tray sensor 1 and DF main PWB (YC20)
DF tray upper surface sensor and DF main
PWB (YC18)
Defective sensor.
Replace DF tray sensor 1 or DF tray upper
surface sensor.
Defective DF tray
Replace the DF tray motor.
motor.
Defective DF main
Replace the DF main PWB and check for
PWB.
correct operation.
Defective connec-
Reinsert the connector. Also check for conti-
tor cable or poor
nuity within the connector cable. If none,
contact in the con-
replace the cable.
nector (4000-sheet
DF tray motor and DF main PWB (YC16)
finisher).
DF tray sensor 1 and DF main PWB (YC22)
DF tray upper surface sensor and DF main
PWB (YC21, YC13)
Defective connec-
Reinsert the connector. Also check for conti-
tor cable or poor
nuity within the connector cable. If none,
contact in the con-
replace the cable.
nector (1000-sheet
DF tray motor and DF main PWB (YC14)
finisher).
DF tray sensor 1 and DF main PWB (YC20)
DF tray upper surface sensor and DF main
PWB (YC18)
Defective sensor.
Replace DF tray sensor 1 or DF tray upper
surface sensor.
Defective DF tray
Replace the DF tray motor.
motor.
Defective DF main
Replace the DF main PWB and check for
PWB.
correct operation.
1-4-74
Check procedures/
corrective measures
2MN/2N1