Installing optional devices

1. Install the optional devices (job separa-
tor, document finisher and/or fax kit
etc.) as necessary.
Installing the cassette heater (option)
1. Install the optional cassette heater as
necessary (see page 1-2-21).

Connect the power cord

1. Connect the power cord to the power
cord connector on rear lower of the
machine.
2. Connect the power plug to the wall out-
let.

Adjusting the image

1. Turn the main power switch on.
2. Check the messages on the operation panel
After completion of warming up, in case to display "Warning for high temperature. Adjust the room tem-
perature." on the operation panel, follow the step 3. (Performing Drum Refresh)
In case to display "Warning for low temperature. Adjust the room temperature." on the operation panel,
install the machine in the other location this message won't be shown.
Installing the machine in a low temperature environment could cause image quality problems.
In case to have no display, follow the step 4 (Performing LSU cleaning).
*: Perform the high altitude settings when a leakage is developed on images in a high altitude installation,
such as in Mexico City.
U140 - AC Calb - High Altitude - Mode 2
3. Performing drum refresh (see the operation guide)
Press the Menu key.
In the Adjust/Maint. menu screen, press cursor key to select Service Setting.
Press the OK key.
In the Service Setting. menu screen, press cursor key to select [Durm].
Press [OK]. A confirmation screen appears.
Press [Yes] ([Left select key]).