Code
Contents
7904

Drum Y EEPROM error

No response is issued from
the device in reading/writing
for 5 ms or more and this
problem is repeated five times
successively.
Mismatch of reading data from
two locations occurs 8 times
successively.
Mismatch between writing
data and reading data occurs
8 times successively.
7911
Developer unit K EEPROM
error
No response is issued from
the device in reading/writing
for 5 ms or more and this
problem is repeated five times
successively.
Mismatch of reading data from
two locations occurs 8 times
successively.
Mismatch between writing
data and reading data occurs
8 times successively.
7912
Developer unit C EEPROM
error
No response is issued from
the device in reading/writing
for 5 ms or more and this
problem is repeated five times
successively.
Mismatch of reading data from
two locations occurs 8 times
successively.
Mismatch between writing
data and reading data occurs
8 times successively.
Causes
Defective connec-
Reinsert the connector. Also check for conti-
tor cable or poor
nuity within the connector cable. If none,
contact in the con-
replace the cable.
nector.
Drum PWB Y and front PWB (YC14)
Front PWB (YC2) and engine PWB (YC10)
Defective drum
Replace the drum unit Y (see page 1-5-29).
PWB Y.
Defective connec-
Reinsert the connector. Also check for conti-
tor cable or poor
nuity within the connector cable. If none,
contact in the con-
replace the cable.
nector.
Developer unit K and front PWB (YC9)
Front PWB (YC2) and engine PWB (YC10)
Defective devel-
Replace the developer unit K (see page 1-5-
oper unit K.
29).
Defective connec-
Reinsert the connector. Also check for conti-
tor cable or poor
nuity within the connector cable. If none,
contact in the con-
replace the cable.
nector.
Developer unit C and front PWB (YC13)
Front PWB (YC2) and engine PWB (YC10)
Defective devel-
Replace the developer unit C (see page 1-5-
oper unit C.
29).
1-4-68
Check procedures/
corrective measures
2MN/2N1