Item No.
U952
Method: [Exec(USB)]
1. Perform shut-down on the operation panel, turn power off(see page P.1-2-19).
2. Insert USB memory in USB memory slot.
3. Turn the main power switch on.
4. Enter maintenance item U952.
5. Select [Execute(USB)].
6. Select the workflow.
Data01 - 06
7. Press the OK key.
Executes maintenance modes defined in a workflow in succession.
Method: [Entry(USB)]
1. Perform shut-down on the operation panel, turn power off (see page p.1-2-19).
2. Insert USB memory in USB memory slot.
3. Turn the main power switch on.
4. Enter maintenance item U952.
5. Select [Entry(USB)].
6. Select the workflow.
Data01 - 06
7. Select the work flow save area.
Data1 - 6
8. Select [Execute].
Exports a workflow housed in a USB flash device to the machine.
Example
Registration is feasible when a USB flash device that stores the commands and text/mainte-
nance ID (editable) is inserted.
File Format: xxx.mwf
!R! MNFC "WFPS";
1.SET UP, 464, 469, 000, 927, 278
2.WARRANTY, 089, 000
3.MK-A, 119, 930, 140, 469, 127, 464, 469, 464, 251
4.MK-B, 119, 930, 140, 464, 469, 464, 251
5.MK-C, 167, 464, 469, 251
WRED;EXIT;
Completion
Press the Back key. The screen for selecting a maintenance item No. is displayed.
Display
Workflow data in the USB flash device
Display
Workflow data in the USB flash device
Display
The area to store workflows in the machine
Description
Description
Description
Description
1-3-147
2MN/2N1-1