Item No.
U140
Setting: [Mag AC]
1. Select the item to be set.
2. Change the setting value using the numeric keys.
Display
C
M
Y
K
B/W*
*: 55 ppm model only.
3. Press the OK key. The value is set.
Setting: [Sleeve Freq]
1. Select the item to be set.
2. Change the setting value using the numeric keys.
Display
Normal
B/W*
Half
3/4*
*: 55 ppm model only.
3. Press the OK key. The value is set.
Setting: [Sleeve Duty]
1. Select the item to be set.
2. Change the setting value using the numeric keys.
Display
Normal
B/W*
*: 55 ppm model only.
3. Press the OK key. The value is set.
Description
Developer magnet roller AC bias
for cyan
Developer magnet roller AC bias
for magenta
Developer magnet roller AC bias
for yellow
Developer magnet roller AC bias
for black
Developer magnet roller AC bias
in black/white mode
Description
Developer sleeve roller fre-
quency
Developer sleeve roller fre-
quency in black/white mode
Developer sleeve roller fre-
quency (half speed)
Developer sleeve roller fre-
quency at 3/4 times of line speed
Description
Developer sleeve roller duty
Developer sleeve roller duty in
black/white mode
Description
Setting
range
0 to 255
200
0 to 255
200
0 to 255
200
0 to 255
160
0 to 255
-
Setting
range
0 to 6200 5345
0 to 6200 -
0 to 6200 5345
0 to 6200 5345
Setting
range
0 to 99
68
0 to 99
-
1-3-75
Initial setting
45ppm
55ppm
200
200
200
160
160
Initial setting
45ppm
55ppm
5511
5345
5345
5345
Initial setting
45ppm
55ppm
68
68
2MN/2N1