Code
Contents
2213

Drum motor M startup error

Drum motor M is not stabilized
within 5 s since the motor is
activated.
2214

Drum motor Y startup error

Drum motor Y is not stabilized
within 5 s since the motor is
activated.
2300

Fuser motor error

After fuser motor is driven, the
ready signal does not turn to L
within 2 s.
After fuser motor is stabilized,
the ready signal is at the H
level for 1 s continuously.
Causes
Defective connec-
Reinsert the connector. Also check for conti-
tor cable or poor
nuity within the connector cable. If none,
contact in the con-
replace the cable.
nector.
Drum motor M and motor control PWB
(YC5)
Motor control PWB (YC3) and engine PWB
(YC9)
Defective drive
Check if the gears rotate smoothly. If not,
transmission sys-
grease the bushes and gears. Check for
tem of motor.
broken gears and replace if any.
Defective drum
Replace the drum motor M.
motor M.
Defective Motor
Replace the Motor control PWB and check
control PWB.
for correct operation.
Defective engine
Replace the engine PWB and check for cor-
PWB.
rect operation (see page 1-5-49).
Defective connec-
Reinsert the connector. Also check for conti-
tor cable or poor
nuity within the connector cable. If none,
contact in the con-
replace the cable.
nector.
Drum motor Y and motor control PWB (YC4)
Motor control PWB (YC3) and engine PWB
(YC9)
Defective drive
Check if the gears rotate smoothly. If not,
transmission sys-
grease the bushes and gears. Check for
tem of motor.
broken gears and replace if any.
Defective drum
Replace the drum motor Y.
motor Y.
Defective Motor
Replace the Motor control PWB and check
control PWB.
for correct operation.
Defective engine
Replace the engine PWB and check for cor-
PWB.
rect operation (see page 1-5-49).
Defective connec-
Reinsert the connector. Also check for conti-
tor cable or poor
nuity within the connector cable. If none,
contact in the con-
replace the cable.
nector.
Fuser motor and feed PWB 1 (YC18)
Feed PWB 1 (YC1) and engine PWB (YC6)
Defective drive
Check if the gears rotate smoothly. If not,
transmission sys-
grease the bushes and gears. Check for
tem of motor.
broken gears and replace if any.
Defective fuser
Replace the fuser motor.
motor.
Defective engine
Replace the engine PWB and check for cor-
PWB.
rect operation (see page 1-5-49).