(8) Detaching and refitting the eject unit

Procedure
1. Pull out the paper conveying unit.
2. Remove the fuser unit (see page 1-5-
40).
3. Remove the connector.
4. Remove four screws and then remove
the eject unit.
5. Check or replace the eject unit and refit
all the removed parts.
Cautions on installing the eject unit
When an additional actuator is installed at the
upper actuator while installing the bridge unit,
inserting the eject unit into the device, use care
that the eject unit does not get in contact with
the eject guide, by keeping its actuator lifted
while inserting.
Connector
Figure 1-5-123
Actuator
Figure 1-5-124
1-5-80
2MN/2N1-1
Eject unit
Screw
Screw
Screws
Eject guides