Completion; Memory Initializing - Kyocera FS-C8600DN Service Manual

Hide thumbs Also See for FS-C8600DN:
Table of Contents

Advertisement

Item No.
U019

Completion

Press the Back key. The screen for selecting a maintenance item No. is displayed.
U021

Memory initializing

Description
Initializes all settings, except those pertinent to the type of machine, namely each counter, ser-
vice call history and mode setting. Also initializes backup RAM according to region specification
selected in maintenance item U252 Setting the destination.
Purpose
Restores the machine parameters to factory default settings.
Method
1. Press the OK key.
2. Select [Execute].
3. Press the OK key. All data other than that for adjustments due to variations between
machines is initialized based on the destination setting.
4. Exit the maintenance mode, perform shut-down, and turn the main power switch to off and on
again. Allow more than 5 seconds between Off and On.
* : An error code is displayed in case of an initialization error.
When errors occurred, turn main power switch off then on, and execute initialization using
maintenance item U021.
Error codes
Codes
0001
Entity error
0002
Counter error
0020
Engine error
Description
Description
1-3-26