Kyocera FS-C8600DN Service Manual page 119

Hide thumbs Also See for FS-C8600DN:
Table of Contents

Advertisement

Item No.
U100
Setting: [Set Charger Freq]
1. Select the item to be set.
2. Change the value using the numeric keys.ll
Display
Generally
B/W*
Half
3/4
*: 55 ppm model only.
3. Press the OK key. The value is set.
Displaying: [Chk Current]
1. The current setting is displayed.
C
M
Y
K
Setting: [Set AC Gain]
1. Select the item to be set.
Auto
Mode1
Mode2
Mode3
Initial setting: Auto
2. Press the OK key. The setting is set.
Completion
Press the Back key. The screen for maintenance item No. is displayed.
Description
Main charger frequency
Main charger frequency in
black/white mode
Main charger frequency in
half speed
Main charger frequency at
3/4 times of line speed
Display
Cyan rush current
Magenta rush current
Yellow rush current
Black rush current
Display
Auto control
Multiplication value 0.95
Multiplication value 1.05
Multiplication value 1.00
Description
Setting
range
7500 to
8807
11280
7500 to
-
11280
7500 to
10690
11280
7500 to
8857
11280
Description
Description
1-3-51
Initial setting
45ppm
55ppm
11022
10690
10690
8857
2MN/2N1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fs-c8650dnEcosys fs-c8600dnEcosys fs-c8650dn

Table of Contents