NEC Univerge SV8100 Features And Specifications Manual page 1468

Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

Issue 5.0
Program
Program Name
Number
22-01-04
System Options for Incoming
Calls – DIL No Answer Recall
Time
24-02-02
System Options for Transfer –
MOH or Ring back on
Transferred Calls
Assign Trunks As Automated Attendant Trunks – Method 1
Program
Program Name
Number
22-02-01
Incoming Call Trunk Setup
22-07-01
DIL Assignment
2 - 1442
Description/Comments
A DIL that rings its programmed
destination longer than this time
diverts to the DIL No Answer Ring
Group (set in Program 22-08).
Enable/Disable MOH on Transfer.
If set to 0, a transferred caller
hears Music on Hold while their
call rings the destination
extension. If set to 1, a transferred
caller hears ring back while their
call rings the destination
extension. For this option to work
with voice mail, the transferred call
must be an unscreened transfer.
Description/Comments
Assign Service Type 4 to each
trunk you want to ring into Voice
Mail as a Direct Inward Line (DIL).
Assign the destination extension
or Department Calling Group for
each DIL incoming trunk. A DIL
rings an extension directly, without
any other Access Map or Ring
Group Programming.
Use Program 22-02 to designate a
DIL trunk.
If all Voice Mail ports are in the
same Extension (Department)
Group, the DIL rings another
Voice Mail port if its assigned port
is busy.
UNIVERGE SV8100
Assigned Data
1
0~64800 (seconds)
(default = 0)
0 = Hold Tone
1 = Ring Back
Tone
(default = 0)
Assigned Data
1
0 = Normal
1 = VRS (second dial
tone if no VRS
installed)
2 = DISA
3 = DID
4 = DIL
5 = E&M Tie line
6 = Delayed VRS
7 = ANI/DNIS
8 = DID(DDI) Mode
Switching
(default = 0)
Extension Number
(maximum eight digits)
(default not assigned)
UM8000 Mail
Level
2
3
Level
2
3

Advertisement

Table of Contents
loading

Table of Contents