The following table lists the operating conditions of the drive:
Operating
Conditions
Operating Variable
Ambient temperature
Relative humidity
Maximum wet bulb
Temperature gradient
1
increase in altitude.
Nonoperating
The following table lists the nonoperating conditions of the drive:
Conditions
Nonoperating Variable
Ambient temperature
Relative humidity
Maximum wet bulb
Temperature gradient
Figure B–5 shows the SCSI ID settings for the RZ26L fixed disk
SCSI ID Jumper
Settings
drive. SCSI ID 7 is reserved for the host SCSI ID.
1
Reduce maximum temperature by 1.8°C (3.24° F) for each 1000-meter (3300-foot)
No special termination is required on workstations.
RZ26L Fixed Disk Specifications
Operating Level
5°C to 55°C
(41°F to 131°F)
10%–90% non-condensing
32°C 90°F
20°C 36°F per hour
Level
–40°C to 66°C
(–40°F to 151°F)
8%–95% (noncondensing)
46°C 115°F
30°C 55°F per hour
Note