TEST
On power-up, the script
is run unless the environment
pst-q
variable
diag_quick
is set to on. With
diag_quick
set to ON,
no TURBOchannel testing is done. When the enironment
variable
is equal to 1 or 2, the
script is run.
diag_section
pst-m
Graphics options are an exception to this rule, since the cnsltest
script is run as part of console determination.
The following command format should be used to execute a
selected test on a TURBOchannel option.
>>> test device_name test_name
where
is the TURBOchannel device name and
device_name
is the name of the test you want to run.
test_name
The following example lists the contents of the option ROM and
the available scripts for the option in TURBOchannel slot 1.
Object scripts are not executable. All items listed are not to be
used as a
.
script_name
>>> t[est] tc1 ls
Return
If an asterisk (*) is at the end of a script, then the object script
will fail if selected. If
test_name
contains a slash or hyphen,
then
should be enclosed in double quotes so that the
test_name
command line parser treats it as a single argument.
The following example runs a diagnostic script on the option
installed in TURBOchannel slot 1.
>>> t[est] tc1 script_name
Return
The following example executes default test scripts on the option
installed in TURBOchannel slot 1.
>>> t[est] tc1
Return
The following example executes a single test script.
>>> t[est] tc1 pst-m
Return