SET
Example: set
To execute the
auto_action
syntax:
Command
>>> se[t] auto[_action] {value}
The following example sets the auto action default to halt.
>>> set auto 3
Result:
AUTO_ACTION = HALT
Example: set
To execute the
bootdef_dev
syntax:
Command
>>> set bootdef_dev {value}
Issuing the
devices.
The following example shows the boot default device being set to
dka200.
>>> set bootdef_dev dka200
Result:
boot = dka200
Example: set
To execute the
boot_osflags
syntax:
Command
>>> set boot_osf[lags] {value}
Table 4–7 describes the values to be used with the boot_osflags
environment and the OpenVMS operating system.
4–38
auto_action command, use the following
set
Return
Return
bootdef_dev command, use the following
set
Return
device command displays the available boot
show
Return
boot_osflags command, use the following
set
Return