Result:
AUTO_ACTION = RESTART
BOOTDEF_DEV = DKA100
BOOT_OSFLAGS = 0,0
ENABLE_AUDIT = ON
BOOT_RESET = ON
SCSI_RESET = 4
DIAG_LOE = OFF
DIAG_QUICK = ON
DIAG_SECTION = 1
ETHERNET = 08-00-2B-2F-F8-E6 , TENBT
LANGUAGE = 3
MOP = OFF
SECURE = ON
RADIX = 0
SCSI_A = 7
TRIGGER = ON
Example: show
To execute the
auto_action
syntax:
Command
>>> sh[ow] auto_a[ction]
The following example shows the action the console takes after a
halt.
>>> sh auto_a
Result:
AUTO_ACTION = RESTART
Example: show
To execute the
bootdef_dev
syntax:
Command
>>> sh[ow] bootdef_d[ev]
The following example shows that the default boot device is
dka400.
>>> sh bootdef_d
Result:
boot = dka400
auto_action command, use the following
show
Return
Return
bootdef_dev command, use the following
show
Return
Return