Example: test
The following example runs all available diagnostics, except
Command
TURBOchannel diagnostics on the Model 300L system.
>>> test
The display on your screen may show some of the following tests:
T-STS-ASIC - OK
T-STS-MEM - Current Test Parameters
T-STS-MEM - lo_addr = 00200000 init_mem = ON test_bad_pages = OFF
T-STS-MEM - hi-addr = 02000000 stop_on_err = ON
T-STS-MEM - Fill mem Wr AAAAAAAA 01800000
T-STS-MEM - Cell Test: FWD RD WR 55555555
T-STS-MEM - Addr Test: Waiting 10 seconds to test refresh
T-STS-MEM - OK
T-STS-NVR - ASSURE_CLOCK_IS_TICKING test
T-STS-SCC - DMA test
T-STS-SCC - LK401 test
T-STS-SCC - OK
T-STS-NI - Ext Lpbk test -
Return
TEST
max_retries = 0