LWAPP Error Messages

Message
LWAPP-3-CDP: Failure sending CDP Update
to Controller. Reason "s"
LWAPP-3-CLIENTERRORLOG: "s"
LWAPP-3-CLIENTEVENTLOG: "s"
LWAPP-3-UNSUPPORTEDRM: Got unsupported
CCX RM Measurement "s" request "d" from
Controller.
LWAPP-5-WRONG_DFS_SLOT: DFS action on
non-DFS radio "d"

Sensor Messages

Message
SENSOR-3-TEMP_CRITICAL: System sensor "d"
has exceeded CRITCAL temperature
thresholds
SENSOR-3-TEMP_NORMAL: "s" temperature
sensor is now normal
SENSOR-3-TEMP_SHUTDOWN: Shuting down the
system because of dangerously HIGH
temperature at sensor "d".
SENSOR-3-TEMP_WARNING: "s" temparature
sensor "d" has exceeded WARNING
temperature thresholds
SENSOR-3-VOLT_CRITICAL: System sensor "d"
has exceeded CRITCAL voltage thresholds
SENSOR-3-VOLT_NORMAL: System sensor
"d"("d") is now operating under NORMAL
voltage
SENSOR-3-VOLT_WARNING: Voltage monitor
"d"("d") has exceeded voltage thresholds
592
Explanation
Could not send access point CDP update to controller
This log message indicates an LWAPP client error event.
The message is logged to help in troubleshooting LWAPP
access point join problems.
This log message indicates an LWAPP client notification
event. The message is logged to help in troubleshooting
LWAPP access point join problems.
Got unsupported CCX radio managment measurement
request from controller.
DFS action on radio b/g
Explanation
One of the measured environmental test points exceeds
the extreme threshold.
One of the measured environmental test points is under
normal operating temperature.
One of the measured environmental test points exceeds
the operating temperature environment of the router.
One of the measured environmental test points exceeds
the warning threshold.
One of the measured environmental test points exceeds
the extreme voltage threshold.
One of the measured environmental test points is under
normal operating voltage.
One of the measured voltage test points indicates that
voltage is out of normal range.
Rockwell Automation Publication 1783-UM006A-EN-P - May 2014
Recommended Action
No action is required.
No action is required.
No action is required.
No action is required.
No action is required.
Recommended Action
Correct the specified condition, or the system
can shut itself down as a preventive measure.
Enter the
show environment all
command to help determine if this is due to
temperature or voltage condition. If this is a
critical temperature warning, please verify
that the router fans are operating and that
the room cooling and air-conditioning are
functioning. This condition could cause the
system to fail to operate properly.
None required.
Investigate the cause of the high
temperature.
Closely monitor the condition and correct if
possible, by cooling the environment.
Correct the specified condition, or the system
can shut itself down as a preventive measure.
Enter the
show environment all
command to help determine if this is due to
voltage condition. This condition could cause
the system to fail to operate properly.
None required.
Check Power Supplies or contact TAC.