Mounting The Access Point To A Network Or Electrical Box - Allen-Bradley Stratix 5100 User Manual

Wireless access point/workgroup bridge
Hide thumbs Also See for Stratix 5100:
Table of Contents

Advertisement

Chapter 2
Install the Stratix 5100 Wireless Access Point/Workgroup Bridge
46
4. Pull approximately 9 in. of cable through the hole. Route the Ethernet and
power cables through the bracket before you attach the bracket to the
ceiling or wall. Route the cables through the main cable access hole and
then through the smaller access hole as shown in this figure.
Figure 16 - Routing the Ethernet and Power Cables
5. (Optional) Use the ground screw to attach the building ground wire to the
mounting bracket.
See
Grounding the Access Point on page 39
instructions.
6. Position the mounting bracket mounting holes (with indents down) over
the pilot holes.
7. Insert a fastener into each mounting hole and tighten.
8. Connect the Ethernet and power cables to the access point.
9. Align the access point feet with the large part of the keyhole mounting
slots on the mounting plate.
When positioned correctly, the cable access cover fits inside the access
point connector bay.
10. Gently slide the access point onto the mounting bracket keyhole slots until
it clicks into place.

Mounting the Access Point to a Network or Electrical Box

Follow these steps to mount an access point to a network box or an electrical box.
1. Position the universal mounting bracket (AIR-AP-BRACKET-2) over the
existing network or electrical box and align the bracket mounting holes
with the box holes.
2. Hold the mounting bracket in place and insert a 6 x 32 x 1/4-in pan head
screw into each of the mounting holes and tighten.
Rockwell Automation Publication 1783-UM006A-EN-P - May 2014