The table below lists the possible status values of the standby access point.
Message
IAPP Standby is Disabled
IAPP - AP is in standby mode
IAPP - AP is operating in active mode
IAPP - AP is operating in repeater mode
Standby status: Initializing
Standby status: Takeover
Standby status: Stopped
Standby status: Ethernet Linktest Failed
Standby status: Radio Linktest Failed
Standby status: Standby Error
Standby State: Init
Standby State: Running
Standby State: Stopped
Standby State: Not Running
When you set up the standby access point, you must enter the MAC address of
the access point that the standby unit monitors. Record the MAC address of the
monitored access point before you configure the standby access point.
The standby access point also must duplicate several key settings on the
monitored access point. These settings are:
• Primary SSID (as well as additional SSIDs configured on the monitored
access point)
• Default IP Subnet Mask
• Default Gateway
• Data rates
• WEP settings
• Authentication types and authentication servers
Check the monitored access point and record these settings before you set up the
standby access point.
Wireless client devices associated to the standby access point lose their
IMPORTANT
connections during the hot standby setup process.
Rockwell Automation Publication 1783-UM006A-EN-P - May 2014
Description
The access point is not configured for standby mode.
The access point is in standby mode.
The standby access point has taken over for the monitored access point
and is functioning as a repeater access point.
The standby access point has taken over for the monitored access point
and is functioning as a repeater access point.
The standby access point is initializing link tests with the monitored
access point.
The standby access point is operating in standby mode and is running link
tests to the monitored access point.
Standby mode has been stopped by a configuration command.
An Ethernet link test failed from the standby access point to the
monitored access point.
A radio link test failed from the standby access point to the monitored
access point.
An undefined error occurred.
The standby access point is initializing link tests with the monitored
access point.
The standby access point is operating in standby mode and is running link
tests to the monitored access point.
Standby mode has been stopped by a configuration command.
The access point is not in standby mode.