Figure 2.6 Output Voltage Connector With Shield - Xantrex XFR 6-200 Operating Manual

Xfr 1200 watt series programmable dc power supply
Hide thumbs Also See for XFR 6-200:
Table of Contents

Advertisement

The 60 V to 600 V (high voltage) models have a 4-terminal, wire clamp output
connector. See inset of Figure 2.6 for a labelled drawing of the wire clamp connector.
The units are shipped with a protective shield attached (see Figure 2.6). To prepare
and connect the load wiring:
3. Use a gloved finger or a blunt tool to push in the circular knockout on the right
4. Insert the bushing of the small black strain relief, screw-side out, through the
5. Strip insulation 0.35" (9 mm) at the end of each of the wires.
6. Loosen the strain relief screw and route the wires through the strain relief.
7. Loosen the connector terminal screw (see inset in Figure 2.6), insert the stripped
8. Ensure that the wires are not pulled too taut between the terminals and the strain
Shield

Figure 2.6 Output Voltage Connector with Shield

(For 60 V to 600 V models.)
Release 3.1
side (recommended) of the shield. After you push in the knockout, twist it until
it detaches from the shield, and discard.
knockout hole, pushing in from the outside of the shield. You will hear a snap as
the strain relief attaches securely to the shield.
wire into the terminal, and tighten the terminal screw securely.
relief. Tighten the strain relief screw.
Strain Relief Screw
Strain Relief
Terminal
Screws
Knockout
Output Voltage Connector For 60 V to 600 V Models
Load Connection
Stripped
Load Wires
0.35" (9 mm)
: 4
S / N
_
T :
O P
U T
T P
O U
D C
+
Negative
Output/Return (−)
Load Wires
Positive Output (+)
Installation
3 2 1
49