Filtering; Interactive Sp Codes - Ricoh B264 Service Manual

Table of Contents

Advertisement

6.5.12 FILTERING

Interactive SP Codes

Overview
The tables in this section are for quick reference. For details about how each SP
code operates and interacts with other SP settings, please refer to the sections that
follow.
Many of the SP codes used for image processing adjustments are interactive in
that they exist as master and slave SPs. Use the master SP codes for gross
adjustment. If you need to fine adjust a master setting, set the master setting to "0"
to access its slave SP codes.
NOTE: In the tables below, the master SP codes are set in bold type. The slave
SP codes are indented and set in normal type.
Keep the following points in mind while you are using these SP codes:
• The slave SP codes cannot be accessed until the master SP is set to "0".
• For the slave SP code settings to take effect, the master SP code must remain
set to "0".
• If the master SP code is reset to any value other than "0", then the slave SP
codes are disabled and their adjustments have no effect on image processing.
• If a master SP code is provided with both a Strength and Level (coefficient)
adjustment, adjust the Strength setting first to achieve the approximate effect
that you want, then do the Level adjustment.
SM
6-33
IMAGE PROCESSING
B264/B265