Communication Switch 02
No
FUNCTION
3
Hang-up decision when a
negative code (RTN or PIN) is
received during G3 immediate
transmission
0: No hang-up, 1: Hang-up
4-7
Not used
Communication Switch 03
No
FUNCTION
0
Maximum number of page
to
retransmissions in a G3
7
memory transmission
Communication Switch 04 - Not used (do not change the settings)
Communication Switch 05 - Not used (do not change the settings)
Communication Switch 06 - Not used (do not change the settings)
Communication Switch 07 - Not used (do not change the settings)
Communication Switch 08 - Not used (do not change the settings)
Communication Switch 09 - Not used (do not change the settings)
Communication Switch 0A
No
FUNCTION
0
Point of resumption of memory
transmission upon redialing
0: From the error page
1: From page 1
1-7
Not used
SM
COMMENTS
0: The next page will be sent even if RTN or PIN is
received.
1: The machine will send DCN and hang up if it
receives RTN or PIN.
This bit is ignored for memory transmissions or if
ECM is being used.
Do not change the settings.
COMMENTS
00 - FF (Hex) times.
This setting is not used if ECM is switched on.
Default setting - 03(H)
COMMENTS
0: The transmission begins from the page where
transmission failed the previous time.
1: Transmission begins from the first page, using
normal memory transmission.
Do not change the settings.
61
BIT SWITCHES
SP No. 1-104-003
SP No. 1-104-004
SP No. 1-104-011
B779