Delivery Server Setting
Provides items for delivery server settings.
5845 1*
FTP Port No.
Sets the FTP port number used when image files to the Scan Router Server.
5845 2*
IP Address (Primary)
Use this SP to set the Scan Router Server address. The IP address under the
transfer tab can be referenced by the initial system setting.
5845 5
Capture Server IP Address
Sets the IP address that is assigned to the PC that the capture server (eCabinet or
ScanRouter) operates. This IP address is set remotely when the delivery server
(Scan Router) IO device is registered. This SP only enables the IP address permit
access to the DNS browser names.
5845 6*
Delivery Error Display Time Netfiles:
Use this setting to determine the length of time the prompt message is displayed
when a test error occurs during document transfer with the NetFile application and
an external device.
5845 8*
IP Address (Secondary)
Specifies the IP address assigned to the computer designated to function as the
secondary delivery server of Scan Router. This SP allows only the setting of the IP
address without reference to the DNS setting.
5845 9*
Delivery Server Model
Allows changing the model of the delivery server registered by the I/O device.
0: Unknown
1: SG1 Provided
2: SG1 Package
3: SG2 Provided
4: SG2 Package
5845 10*
Delivery Svr Capability
Changes the capability of the registered that the I/O device registered.
[0~255 / 0 / 1]
(7) [0000 0000] (1)
Bit7 = 1 Comment information exists
Bit6 = 1 Direct specification of mail address possible
Bit5 = 1 Mail RX confirmation setting possible
Bit4 = 1 Address book automatic update function exists
Bit3 = 1 Fax RX delivery function exists
Bit2 = 1 Sender password function exists
Bit1 = 1 Function to link MK-1 user and Sender exists
Bit0 = 1 Sender specification required (if set to 1, Bit6 is set to "0")
5845 11
Delivery Svr.Capability (Ext)
These settings are for future use. They will let you increase the number of
registered devices (in addition to those registered for SP5845 010).
There are eight bits (Bit 0 to Bit 7). All are unused at this time.
SM
SERVICE PROGRAM MODE TABLES
[0~65535 / 3670 / 1]
Range: 000.000.000.000 ~ 255.255.255.255
[0~999 / 300 / 1]
Range: 000.000.000.000 ~ 255.255.255.255
[0~4/ 0 / 1]