NCU PARAMETERS
Address
68052F
Busy tone OFF time: range 3
680530
Busy tone ON time: range 4
680531
Busy tone OFF time: range 4
680532
Busy tone continuous tone detection
time
680533
Busy tone signal state time tolerance for all ranges, and number of cycles
required for detection (a setting of 4 cycles means that ON-OFF-ON or OFF-ON-
OFF must be detected twice).
Tolerance (±)
Bit
1
0
0
1
1
Bits 7, 6, 5, 4 - number of cycles required for cadence detection
680534
International dial tone frequency
upper limit (high byte)
680535
International dial tone frequency
upper limit (low byte)
680536
International dial tone frequency
lower limit (high byte)
680537
International dial tone frequency
lower limit (low byte)
680538
International dial tone detection time
680539
International dial tone reset time
(LOW)
68053A
International dial tone reset time
(HIGH)
68053B
International dial tone continuous
tone time
68053C
International dial tone permissible
drop time
68053D
International dial wait interval (LOW)
68053E
International dial wait interval (HIGH)
68053F
Country dial tone upper frequency
limit (HIGH)
680540
Country dial tone upper frequency
limit (LOW)
680541
Country dial tone lower frequency
limit (HIGH)
680542
Country dial tone lower frequency
limit (LOW)
680543
Country dial tone detection time
680544
Country dial tone reset time (LOW)
680545
Country dial tone reset time (HIGH)
680546
Country dial tone continuous tone
time
B779
Function
0
0
75% Bits 2 and 3 must always
1
50% be kept at 0.
0
25%
1
12.5%
Unit
20 ms
Hz (BCD)
Hz (BCD)
20 ms
Hz (BCD)
20 ms
88
Remarks
If both addresses contain
FF(H), tone detection is
disabled.
If both addresses contain
FF(H), tone detection is
disabled.
If 680538 contains FF,
the machine pauses for
the pause time (68053D /
68053E).
Belgium: See Note 2.
If both addresses contain
FF(H), tone detection is
disabled.
If both addresses contain
FF(H), tone detection is
disabled.
If 680543 contains FF,
the machine pauses for
the pause time (680548 /