Ricoh B264 Service Manual page 767

Table of Contents

Advertisement

Code
Meaning
6-00
G3 ECM - T1 time out
during reception of facsimile
data
6-01
G3 ECM - no V.21 signal
was received
6-02
G3 ECM - EOR was
received
6-04
G3 ECM - RTC not detected
6-05
G3 ECM - facsimile data
frame not received within 18
s of CFR, but there was no
line fail
6-06
G3 ECM - coding/decoding
error
6-08
G3 ECM - PIP/PIN received
in reply to PPS.NULL
6-09
G3 ECM - ERR received
6-10
G3 ECM - error frames still
received at the other end
after all communication
attempts at 2400 bps
6-21
V.21 flag detected during
high speed modem
communication
6-22
The machine resets the
sequence because of an
abnormal handshake in the
V.34 control channel
6-99
V.21 signal not stopped
within 6 s
13-17
SIP user name registration
error
13-18
SIP server access error
SM
Suggested Cause/Action
• Try adjusting the rx cable equalizer.
• Replace the FCU or NCU.
• Check the line connection.
• Check connections from the NCU to the FCU.
• Check for a bad line or defective remote terminal.
• Replace the FCU or NCU.
• Check the line connection.
• Check connections from the NCU to the FCU.
• Check for a bad line or defective remote terminal.
• Replace the FCU or NCU.
• Try adjusting the rx cable equalizer
Cross reference
• Rx cable equalizer - G3 Switch 07 (PSTN)
• Defective FCU.
• The other terminal may be defective.
• The other end pressed Stop during
communication.
• The other terminal may be defective.
• Check for a noisy line.
• Adjust the tx levels of the communicating
machines.
• See code 6-05.
• Check for line noise.
• Adjust the tx level (use NCU parameter 01 or the
dedicated tx parameter for that address).
• Check the line connection.
• Defective remote terminal.
• The other terminal may be defective or
incompatible.
• Check for line noise.
• If the same error occurs frequently, replace the
FCU.
• Defective remote terminal.
• Replace the FCU.
• Double registration of the SIP user name.
• Capacity for user-name registration in the SIP
server is not sufficient.
• Incorrect initial setting for the SIP server.
• Defective SIP server.