Ricoh B264 Service Manual page 238

Table of Contents

Advertisement

SERVICE CALL CONDITIONS
545
A
Fusing lamp remains on
After warm-up the fusing lamp remains
at full power for 10 seconds without the
hot roller rotating.
546
A
Fusing ready temperature unstable
The fusing temperature is fluctuating.
547
D
Zero cross signal error
One of the following occurred:
1) The fusing relay remained off for 50
ms after power on and continued to
remain off after the after 3 attempts
to detect the zero-cross signal.
2) During 11 zero-cross signal
detections, two zero-cross signal
detections were below 44 Hz.
3) The zero-cross signal could not be
detected within 3 sec. after the
fusing relay switched on.
548
A
Fusing unit installation error
The machine cannot detect the fusing
unit when the front cover and right
cover are closed.
557
C
Zero-cross frequencyover
The applied power ac frequency was
detected less than 66 Hz more than 10
times, or less than 44 Hz one time.
599
D
1-Bin tray motor lock
A 1-bin tray motor lock signal is not
detected for more than 300 ms during
rotation.
601
D
Communication error between BICU
and scanner unit
Within 800 ms after power on, after 3
attempts the BICU does not
communicate with the SIB via the serial
line.
610
D
Communication timeout error between
BICU and ADF
The BICU cannot receive a response
within 100 ms after 3 attempts after
sending data to the ARDF.
611
D
Communication break error between
BICU and ADF
The BICU receives a break signal from
the ADF main board.
B264/B265
• Thermistor is out of position.
• Thermistor connection loose
• Fusing unit connector loose
• Switch the main switch off and on
• Defective fusing relay, replace the
PSU
• Fusing unit is not installed
• Fusing unit connection loose
• Nose on the ac power line
• 1-bin tray motor locked from overload
• 1-bin tray motor defective
• 1-bin tray motor connection loose
• Serial line connecting the BICU and
SIB defective
• External noise on the serial line
• SIB board defective
• BICU board defective
• BICU board and ADF main board
serial line connection defective
• External noise
• ADF main board defective
• BICU board defective
• Serial line connecting BICU and ADF
unstable
• External noise
• ADF main board defective
• BICU board defective
4-10