Ricoh B264 Service Manual page 302

Table of Contents

Advertisement

SERVICE PROGRAM MODE TABLES
5212
Page Numbering
5212 3
Duplex Printout Left/Right Position
5212 4
Duplex Printout High/Low Position
5179*
Bypass Size Error
This SP determines whether a paper size error prompt appears when the machine
detects the wrong paper size for the job and jams during feed from the bypass tray.
[0~1/0/1]
0: Off
1: On
5302
Set Time DFU
Sets the time clock for the local time. This setting is done at the factory before
delivery. The setting is GMT expressed in minutes.
[–1440~1440/1 min.]
JA: +540 (Tokyo)
NA: -300 (NY)
EU: +6- (Paris)
CH: +480 (Peking)
TW: +480 (Taipei)
AS: +480 (Hong Kong)
5305
Auto Off Function Release Setting
This SP prevents the user from easily disabling the auto off timer. This is done to
conform with international Energy Star standards that specifically state that the user
shall not be able to easily switch off the auto off feature.
0: On (Auto Off cannot be released
1: Off (Auto Off can be released)
B264/B265
Horizontally positions the page numbers
printed on both sides during duplexing.
[–10~+10/1 mm]
0 is center, minus is left, + is right.
Vertically positions the page numbers printed
on both sides during duplexing.
[–10~+10/1 mm]
0 is center, minus is down, + is up.
5-38
SM

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

B265Aficio 3035Aficio 3045