Minimum startup configuration

Field Replaceable Units (FRU)
If the server does not start up or other problems occur, it may be necessary to
take the system down to its most basic configuration in order to isolate the
defective component.
The minimum startup configuration consists of the following components and
cables:
Component
System board
CPU with CPU heat sink
1 memory module
Front panel module
Power supply unit
Table 8: Minimum startup configuration - components
Cable
Front panel cable
Power cable
Table 9: Minimum startup configuration - cables
Ê Shut down the server as described in section
page
59.
Ê Remove the AC power cord from the cable tie or cable clamp and disconnect
it from the system.
Ê Take the system down to its minimum startup configuration.
Ê Reconnect the AC power cord to the power supply unit and secure it with a
cable tie or cable clamp.
Ê Connect a keyboard, mouse and display to the server.
460
Notes
no TPM, UFM or expansion cards installed
installed in DIMM slot 1A
Notes
Upgrade and Maintenance Manual
"Shutting down the server" on