Modules with Electrostatic-Sensitive Devices
Modules with electrostatic-sensitive devices are identified by the following
sticker:
Figure 1: ESD label
When you handle components fitted with ESDs, you must always observe the
following points:
Switch off the system and remove the power plugs from the power outlets
before installing or removing components with ESDs.
You must always discharge static build-up (e.g. by touching a grounded
object) before working with such components.
Any devices or tools that are used must be free of electrostatic charge.
Wear a suitable grounding cable that connects you to the external chassis
of the system unit.
Always hold components with ESDs at the edges or at the points marked
green (touch points).
Do not touch any connectors or conduction paths on an ESD.
Place all the components on a pad which is free of electrostatic charge.
I
For a detailed description of how to handle ESD components, see the
relevant European or international standards (EN 61340-5-1,
ANSI/ESD S20.20).