Ê If LAN teaming has been active, you will need to restore the configuration
using the LAN driver utility after replacing the system board.
I
For details, refer to the relevant LAN driver manual.
5.2.18 Switching off the ID indicator
Press the ID button on the front panel or use ServerView Operations Manager
to switch off the ID indicator after the maintenance task has been concluded
successfully.
I
For further information, refer to section
page 55
or to the "ServerView Suite Local Service Concept (LSC)"
manual.
Using the ID button on the front panel
Ê Press the ID button on the front panel to switch off the ID indicators.
Using ServerView Operations Manager
Ê In ServerView Operations Manager Single System View and press the Locate
button in the title bar to switch off the ID indicator.
5.2.19 Performing a fan test after replacing a defective fan
After replacing a defective system fan or power supply unit containing a
defective fan, the fan error indicators will stay lit until the next fan test. By
default, a fan test is automatically started every 24 hours. The first automatic fan
test being performed after replacing a fan will turn off the fan error indicator.
If you want to start the fan test manually, you can do so by following the
description below:
Executing the fan test via the iRMC Web interface
Ê Log into the iRMC web interface.
Ê Under Sensors select Fans.
Ê Select the replaced fan in the system fans group and click Start Fan Test.
RX100 S7
Upgrade and Maintenance Manual
Basic software procedures
"Locating the defective server" on
99