Opening The Rack Door; Shutting Down The Server - Fujitsu PRIMERGY RX100 S7 Upgrade And Maintenance Manual

Server
Hide thumbs Also See for PRIMERGY RX100 S7:
Table of Contents

Advertisement

4.2

Opening the rack door

I
The following description only applies to the PRIMECENTER rack. For
further instructions on opening or closing the 19-inch rack, please refer
to the "19-inch Rack for PRIMERGY and RM systems" assembly guide,
available online at
Suite DVD 2 supplied with your PRIMERGY server.
The PRIMECENTER rack is equipped with a split front door. The left-hand door
contains an interlocking system that can be locked and opened with a key.
Optionally, a revolving door knob can be mounted for key-less locking. To
unlock and open the rack, proceed as follows:
Ê Insert and turn the key by counter-clockwise by 180 degrees.
If applicable, turn the door knob counter-clockwise by 180 degrees.
Ê Open the left-hand door first, then the right-hand door.
I
For further information, refer to the "PRIMECENTER Rack System"
assembly guide available online at
ServerView Suite DVD 2 supplied with your PRIMERGY server.
4.3

Shutting down the server

V
CAUTION!
Follow the safety instructions in chapter
page
43.
I
This step is only required when upgrading or replacing non-hot plug
components.
Ê Inform the system administrator that the server will be shut down and put
offline.
Ê Terminate all applications.
Ê Shut down the server.
I
If the system is running an ACPI-compliant operating system, the
pressing the On / Off button will performs a graceful shutdown.
Ê Switch on the ID indicator on the front and rear connector panels of the
server as described in section
RX100 S7
http://manuals.ts.fujitsu.com
"Locating the defective server" on page
Upgrade and Maintenance Manual
Basic hardware procedures
or from the ServerView
http://manuals.ts.fujitsu.com
"Important information" on
or from the
55.
59