Basic software procedures
Ê Press the On / Off button to start up the server.
The system will detect the USB stick and the BIOS recovery process will be
performed.
V
CAUTION!
Do not interrupt the BIOS upgrade process after it has started. If the
process is interrupted, the system BIOS may be permanently
corrupted.
Ê After completion of the flash process, shut down the server.
Ê Remove the top cover as described in section
page
64.
Ê Disable BIOS recovery mode using the onboard jumpers:
I
For detailed information on jumper settings, refer to section
on page 459
Ê Close the top cover as described in section
iRMC recovery procedure
I
For the Japanese market, follow the instructions provided separately.
Ê Prepare a USB stick including the bootable iRMC firmware update image.
Ê Shut down the server as described in section
page 59
and disconnect it from the mains.
Ê Connect the USB stick to the USB connector.
I
Ensure that only the USB device with the iRMC firmware is connected
to the USB connector. Remove all other USB devices temporarily.
Ê Connect the server to the mains while pushing the ID button on the front
panel. Ask a second person to help you if necessary.
Ê Ensure that the Global Error indicator and the ID indicator are flashing to
indicate that the server is entering the iRMC recovery state.
Ê Press the Power On / Off button. The system starts the POST process.
I
In iRMC reocovery mode, the "FUJITSU" logo does not show up.