Possible values for AuthProtocol:
0 – none
1 - MD5
2 - SHA-1
Possible values for PrivProtocol:
0 – none
1 – DES
3 - AES128
5.
To end the PuTTY configuration session, type a full-stop (".") on an empty line; the
device responds with the following:
INI File replaced
6.
To save the configuration to the non-volatile memory, type sar ; the device reboots with
IPSec enabled.
5.9.2
Configuring EMS to Operate with a Pre-configured SNMPv3
System
The procedure below describes how to configure the device with a pre-configured SNMPv3.
To configure the EMS to operate with a pre-configured SNMPv3 system:
1.
In the MG Tree, select the required Region to which the device belongs, and then
right-click the device.
2.
From the shortcut menu, choose Details
3.
Select the SNMPv3 option, configure the SNMP fields, and then click OK
4.
Open the 'SNMPv3 Users' screen (
5.
Select the tabs arrow button, and then from the shortcut menu, choose
'SNMPv3 Users' table is refreshed with the values that you entered in Step 3.
6.
Click the
SIP User's Manual

Figure 5-11: MG Information Screen

Save button; the EMS and the device are now synchronized.
; the 'MG Information' screen appears.
Network tab > SNMPv3 Users