Configuring Basic Sip Parameters - AudioCodes Mediant 2000 User Manual

Media gateway
Hide thumbs Also See for Mediant 2000:
Table of Contents

Advertisement

5.5

Configuring Basic SIP Parameters

This section describes how to configure the device with basic SIP control protocol
parameters using the EMS.
To configure basic SIP parameters:
1.
In the MG Tree, select the device that you want to configure.
2.
On the Tab bar, click Protocol Definition; the 'SIP Protocol Definitions' frame
appears.
3.
Select the Coders
a.
Click the
b.
Double-click each field to enter values.
c.
Right-click the new entry, and then choose Unlock Rows
4.
Select the
a.
Set 'Proxy Used' to Yes.
b.
(Optional) In the 'Proxy Name' field, enter the Proxy's name. The Proxy name
replaces the Proxy IP address in all SIP messages. This means that messages
are still sent to the physical Proxy IP address, but the SIP URI contains the Proxy
name instead. When no Proxy is used, the internal routing table is used to route
the calls.
c.
Click the
d.
Enter the IP address of the Proxy Server.
e.
Right-click the new entry, and then choose Unlock Rows.
SIP User's Manual
tab; the Coders screen is displayed.
button to add a new Coder entry, and then click Yes
Proxy Server
tab.
button, and then click Yes
212
.
to confirm.