3.2

Configuring Basic SIP Parameters

Once you have completed the previous sections, you are ready to start configuring the
device using the Web interface. For information on how to fully configure the device, refer to
the device's User's Manuals.
Note:
To configure basic SIP parameters:
1.
Access the Web interface.
2.
Select the voice coders used by the device that best suits your VoIP network in the
'Coders Table' page (Configuration tab > Protocol Configuration menu > Protocol
Definition submenu > Coders).
3.
When operating with a Proxy server, perform the following (otherwise, skip to Step 4):
a.
In the 'Proxy & Registration' page (Configuration tab > Protocol Configuration
menu > Proxies/IpGroups/Registration submenu > Proxy & Registration):
b.
In the 'Proxy Sets Table' page (Configuration tab > Protocol Configuration
menu > Proxies/IpGroups/Registration submenu > Proxy Sets Table), define
the IP address(s) of the Proxy server(s). When no Proxy is used, the internal
routing table is used to route the calls.
4.
Enable the device's channels in the 'Trunk Group Table' page (Configuration tab >
Protocol Configuration menu > Trunk Group submenu > Trunk Group).
5.
Configure the Trunks in the 'Trunk Settings' page (Configuration tab > PSTN
Settings menu > Trunk Settings). For a brief description, refer to 'Configuring PSTN
Trunks' on page 43.
6.
If a Proxy server is not implemented, map outgoing calls to IP addresses in the 'Tel to
IP Routing' (or Outbound IP Routing if the IP-to-IP/SBC feature is enabled) page
(Configuration tab > Protocol Configuration menu > Routing Tables submenu >
Tel to IP Routing).
7.
Save your settings to the flash memory and reset the device (refer to 'Saving and
Resetting the Device' on page 45).
Tip:
Installation Manual
This section is applicable only to SIP devices.
Set the 'Use Default Proxy' field to "Yes".
(Optional) In the 'Proxy Name' field, enter the Proxy's name. The Proxy
name replaces the Proxy IP address in all SIP messages. This means that
messages are still sent to the physical Proxy IP address, but the SIP URI
contains the Proxy name instead.
To enable the device to register to a Proxy/Registrar server (at power up and
every user-defined interval - 'Registration Time' parameter), set 'Enable
Registration' to "Enable"'
Once the device is configured, backup your settings by saving the
configuration (ini) file to your PC. This saved file can later be used, if
necessary, to restore configuration settings (refer to 'Backing Up and
Restoring Configuration' on page 48).