create cfm md
<string 22> {md_index <uint 1-4294967295>} level <int 0-7>
config cfm md
[<string 22> | md_index <uint 1-4294967295>] {mip [none | auto |
explicit] | sender_id [none | chassis | manage | chassis_manage]}
create cfm ma
<string 22> {ma_index <uint 1-4294967295>} md [<string 22> |
md_index <uint 1-4294967295>]
config cfm ma
[<string 22> | ma_index <uint 1-4294967295>] md [<string 22> |
md_index <uint 1-4294967295>] {vlanid <vlanid 1-4094> | mip [none | auto |
explicit | defer] | sender_id [none | chassis | manage | chassis_manage | defer]
| ccm_interval [10ms | 100ms | 1sec | 10sec | 1min | 10min] | mepid_list [add |
delete] <mepid_list>}
create cfm mep
<string 32> mepid <int 1-8191> md [<string 22> | md_index <uint 1-
4294967295>] ma [<string 22> | ma_index <uint 1-4294967295>] direction [inward |
outward] port <port>
config cfm mep
[mepname <string 32> | mepid <int 1-8191> md [<string 22> |
md_index <uint 1-4294967295>] ma [<string 22> | ma_index <uint 1-4294967295>]]
{state [enable | disable] | ccm [enable | disable] | pdu_priority <int 0-7> |
fault_alarm [all | mac_status | remote_ccm | error_ccm | xcon_ccm | none] |
alarm_time <centisecond 250 -1000> | alarm_reset_time <centisecond 250-1000>}
delete cfm mep
[mepname <string 32> | mepid <int 1-8191> md [<string 22> |
md_index <uint 1-4294967295>] ma [<string 22> | ma_index <uint 1-4294967295>]]
delete cfm ma
[<string 22> | ma_index <uint 1-4294967295>] md [<string 22> |
md_index <uint 1-4294967295>]
delete cfm md
[<string 22> | md_index <uint 1-4294967295>]
enable cfm
disable cfm
config cfm ports
<portlist> state [enable | disable]
show cfm ports
<portlist>
show cfm
{[md [<string 22> | md_index <uint 1-4294967295>] {ma [<string 22> |
ma_index <uint 1-4294967295>] {mepid <int 1-8191>}} | mepname <string 32>]}
show cfm fault
{md [<string 22> | md_index <uint 1-4294967295>] {ma [<string 22>
| ma_index <uint 1-4294967295>]}}
show cfm port
<port> {level <int 0-7> | direction [inward | outward] | vlanid
<vlanid 1-4094>}
cfm loopback
<macaddr> [mepname <string 32> | mepid <int 1-8191> md [<string 22>
| md_index <uint 1-4294967295>] ma [<string 22> | ma_index <uint 1-4294967295>]]
{num <int 1-65535> | [length <int 0-1500> | pattern <string 1500>] | pdu_priority
<int 0-7>}
Extreme Networks EAS 200-24p Switch CLI Manual