sTLB Way Reduction
When a way reduction condition is recognized for the sTLB way W (W = 0 or 1),
hardware executes the following way reduction procedures:
1. When only one way in sTLB is active because of previous way reductions:
2. Regardless of how many ways were previously active, way reduction occurs:
P.11
Handling of Extended UPA Bus Interface
Error
This section specifies how SPARC64 V handles UPA address and data bus errors.
P.11.1

Handling of Extended UPA Address Bus Error

The extended UPA address bus is protected by a parity bit attached to every 8 bits.
When the SPARC64 V processor detects a parity error in the extended UPA address
bus, the processor takes one of the following actions, depending on the OPSR setting:
1. Upon detection of the error, the processor enters the CPU fatal error state.
2. Upon detection of the autonomous urgent error
processor tries to continue running. However, in some situations, the processor
detects a fatal error and enters the CPU fatal error state.
P.11.2

Handling of Extended UPA Data Bus Error

The extended UPA data bus is protected by a single-bit error correction and double-
bit error detection ECC code attached to every doubleword.
Error marking is applied to the data transmitted through the extended UPA data
bus. The SPARC64 V processor will detect the following three types of errors at the
extended UPA data bus interface:
Correctable error (1-bit error)
Release 1.0, 1 July 2002
The previously reduced way is reactivated.
Hardware reduces the way and invalidates all entries in sTLB way W. Way W
will never be refilled.
The restrainable error
ASI_AFSR.DG_L1$U2$STLB
is reported to software.
, the
ASI_UGESR.AUG_SDC
F. Chapter P
Error Handling
197