MERLIN LEGEND Communications System Release 5.0
Maintenance and Troubleshooting 555-650-140
Error Logs, Access Logs, and System Inventory
Error Logs
Table 2--2 Continued
Error
Codes
Description
9803
MCARD 12-VOLT ERROR:
The memory card voltage is
incorrect.
9C01
NW REJECTS SPID:
Service on the link has been lost.
9C03
LINK ESTABLISHMENT FAIL:
Service on the link has been lost.
9C04
NW NOT RESPOND TO SETUP:
Service on the link has been lost.
9C05
NW NOT RESPOND TO RELEASE:
Service on the link has been lost.
9C07
ENDPOINT UNINIT (L2/L3):
Service on the link is uninitialized.
Action
Reset the card and try again. If the
problem persists, replace the card and
try again. If the problem still persists,
replace the processor.
Check the programmed SPID for
correctness. If it is incorrect, modify the
programming; otherwise, contact the
central office to correct the problem.
Check that the line is securely connected
to the port and that the LEDs on the
board show proper operation. If the card
appears to be working properly, check
that the line has been activated by the
central office.
The network is not responding to the
MERLIN LEGEND messages. Contact
the central office to correct the problem.
The network is not responding to the
MERLIN LEGEND messages. Contact
the central office to correct the problem.
The link is in the process of initializing. If
this error remains logged for more than a
half hour, try re-plugging the DSL. If the
problem persists, contact the central
office to correct the problem.