Error Logs
Table 2-2. Error Codes
Error
Codes
Description
0001
TIMEOUT COLD START:
System programming is okay.
0002
POWER UP WARM START:
System programming is okay.
0003
SOFTWARE COLD START:
System programming is okay.
SOFTWARE WARM START: System
0004
programming is okay.
0005
Reset - DIAGNOSTIC SWITCH:
0006
INCOMPLETE COLD START:
System was cold-started while a
restart was in progress.
0007
SANITY TIMEOUT RESET:
Faulty software, module, carrier, or
processor sanity timer.
0008
MAX RESET COUNT EXCEEDED:
System was cold-started (System
Reset) because too many warm
starts occurred.
System programming is okay.
Action
No action required; however, if problem
persists, troubleshoot the processor.
No action required; however, if problem
persists, troubleshoot the processor.
If problem persists, troubleshoot the
processor.
If problem persists, troubleshoot the
processor.
If problem persists, troubleshoot the
processor.
Troubleshoot module and or processor.
If problem persists, troubleshoot the
processor.