MERLIN LEGEND Communications System Release 5.0
Maintenance and Troubleshooting 555-650-140
Error Logs, Access Logs, and System Inventory
Error Logs
Table 2-2 Continued
Error
Codes
Description
0009
FRIGID START:
System was restarted and initialized
to default programming.
This error is also logged after a
System Erase.
000A
POWER UP COLD START:
A RAM failure was detected in the
processor.
System programming is okay.
000B
CARD INSERTED/REMOVED:
000C
SLOT STREAM CNT EXCEEDED:
Slot has generated excessive
interrupts.
000D
FMWR NOT IN STANDBY MODE:
Module firmware is not in standby
mode.
000E
COMMAND BUFFER FULL:
000F
TASK RUNNING TOO LONG:
0010
INVALID SLOT INTERRUPT:
Cannot determine module
responsible for generating the
interrupt.
0011
STACK OVERFLOW:
Processor problem.
Action
If the processor was removed while in
use, the system may perform a frigid
start due to loss of system programming.
Restore system as described in System
Programming and Maintenance (SPM) ,
or in
Appendix D, ''Backing Up with a
Memory
Card''.
If problem persists, troubleshoot the
processor.
No action required.
If problem persists, troubleshoot the
module.
If problem persists, troubleshoot the
module.
If problem persists, troubleshoot the
processor and module.
No action required: however, if problem
persists, troubleshoot the processor.
Troubleshoot modules and replace if
necessary. If problem persists,
troubleshoot the processor.
Troubleshoot the processor.
Continued on next page
Issue 1
June 1997
Page 2-7