Unit Load Calculation Worksheet
Unit Load Worksheet
9. Try to exchange modules between carriers to reduce the unit loads for
slots five and six through 27. (Remember that the 100D, 400, 400
GS/LS/TTR, 800 GS/LS-ID, 800, 800 NI-BRI, and 800 GS/LS modules
have unit loads of 0.0.) Repeat Steps 1 through 8 to recalculate unit
loads for new configuration.
If the exchange reduces the unit load for slots five and six through 27 or
less, power is sufficient.
If the exchange does not reduce the unit loads for slots 5 and 6 through
27, install wall power units for the appropriate number of telephones to
reduce the unit load to 27.
NOTE:
Empty slots are not permitted between modules.