Lucent Technologies MERLIN LEGEND Release 5.0 Maintenance And Troubleshooting Manual page 185

Communications system
Hide thumbs Also See for MERLIN LEGEND Release 5.0:
Table of Contents

Advertisement

MERLIN LEGEND Communications System Release 5.0
Maintenance and Troubleshooting 555-650-140
Control Unit Problems
800 NI-BRI Module Problems
Table 4-7 Continued
Result
Description
Code
BRI facility that is
OKNOH
not part of an
(Release
4.1 and
MLHG is
later. See
provisioned with
OK for
functioning voice
Release
and data
4.0 and
capabilities
earlier)
No or incorrect
SPID
(Release
SPID
4.1 and
administration
later)
MERLIN
LG
LEGEND BRI
error on that
facility
MERLIN
ADMCO
LEGEND
(Release
administration
4.0 and
error and/or CO
earlier)
provisioning error
on that facility
Corrective Action
No action is required if non-MLH voice and data
functionalities are expected. If MLH is expected, verify
that the MLHG DN is not present and, if so, administer
it and rerun the test.
Check that the facility is administered with the SPID
provided by the LEC and rerun the test. If the error
persists, contact the LEC.
This result should never appear; if it does, contact the
NSAC.
Check that the facility is administered with the DN
provided by the CO. If the DN was not administered
properly, correct it and rerun the test. If the error
persists, perform the appropriate set of tests (voice only,
data only, or voice and data) and record the results
before contacting the LEC:
Outgoing Voice Call Test
Incoming Voice Call Test
and/or
Outgoing Data Call Test
Incoming Data Call Test
The possible causes for this error are:
Incorrect DN
(Error identified at Incoming Voice/Data Call Test,
Step 2)
Incoming calls fail.
Any of the causes listed for CO-V and CO-D
Issue 1
June 1997
Page 4-95
Continued on next page

Advertisement

Table of Contents
loading