Control Unit Problems
800 NI-BRI Module Problems
Table 4-7 Continued
Result
Description
Code
No voice or
MLHDV
(Release
data hunting,
4.1 and
or
later)
Incorrect
voice and data
MLHG DN if
MLHG DN is
present, or
Voice and
data hunting
was observed
with no
MLHG DN
BRI facility that is
OKH
(Release
part of an MLHG is
4.1 and
provisioned with
later)
functioning voice
and data
capabilities
Corrective Action
The facility is correctly administered and established
with layers 1, 2, and 3 with functioning voice and data
data capabilities.
Combination of the causes for MLHV and MLHD.
No action is required if the MLH voice and data
functionalities are expected. If MLH is not expected,
verify that the MLHG DN is present and, if so, remove it
and rerun the test.