MERLIN LEGEND Communications System Release 5.0
Maintenance and Troubleshooting 555-650-140
Error Logs, Access Logs, and System Inventory
Error Logs
Table 2-2 Continued
Error
Codes
Description
7802
SANITY INT NOT GENERATED:
Only applies to modules that have
extension jacks.
7803
NO PORT BOARDS AVAILABLE:
This error is reported when modules
are not present.
7804
INVALID SANITY RESPONSE:
This error occurs when a sanity test
gets invalid responses. Applies only
to modules that have extension
jacks.
7805
INVALID SLOT NUMBER:
Rarely occurs.
Software could not process an event
detection because the slot number
was invalid.
7806
NOT IN STANDBY MODE:
Reported during cold start or
background check.
7807
SELF TEST NOT COMPLETED:
Reported during cold start.
7808
TEST RESULT REGISTER BAD:
A module error or processor error
resulted while running test.
7809
TEST STATUS REGISTER BAD:
A module error or processor error
resulted while running test.
Action
Reset the board . If problem persists,
troubleshoot the module.
No action required. Delete this entry from
the transient log.
Reset the board . If problem persists,
troubleshoot the module.
No action required; however, if problem
persists, restart the system.
Reset the board . If problem persists,
troubleshoot the module.
Reset the board . If problem persists,
troubleshoot the module.
Reset the board. If problem persists,
troubleshoot the module.
Reset the board. If problem persists,
troubleshoot the module.
Continued on next page
Issue 1
June 1997
Page 2-17