MERLIN LEGEND Communications System Release 5.0
Maintenance and Troubleshooting 555-650-140
Control Unit Problems
Processor Problems
Console Display/Instructions
Select Yes.


Slot 00 System Erase:
System will be down...
Do you want to continue?
Yes
No
Exit
System Erase:
Full-default Restarting
Forced Installation/Upgrade of System
Software
!
CAUTION:
Forced installation should be performed only under emergency
situations in which on-board system software has been corrupted.
All existing system programming will be erased by this procedure.
Beginning with Release 3.0, the system software can be installed or upgraded
through the PCMCIA interface slot on the processor module. Use the following
procedure when:
System software becomes corrupted. Attempt to reinstall software
with a Forced Installation memory card. If that does not solve the
problem, replace the processor module.